NO-CON-DROP

No-Con-Drop is a precoated steel sheet with moisture absorbing fibre fabric on the underside. The fabric can be applied to R32/1000, 13/3 Corrugated and Metile profile sheets.

Typical buildings

• Uninsulated Warehouses
• House extensions
• Garages & Car ports
• Parapet roofs
• Agricultural Building
• Open Shelters

The moisture absorbing function

Condensation on the underside of the profile sheets occurs when the temperature of the sheet is equal to or lower than the dew point of the air under the sheet. The fibre fabric has the capability to absorb at least 200 grams of water per square meter which is considered to be more than sufficient for most applications. Between the condensation periods the fibre fabric dries out. For this reason the building must be ventilated.

Detail Design of Roofs

Profiled sheets with No Con Drop are installed in the same way as sheets without fibre fabric with some exceptions. Due to the capilliary action properties of the fibre the following precautions MUST be made to prevent that water is drawn back under the sheet at lower sheet tails and at endlaps.

Caution

  • No-Con-Drop should not be installed directly on water absorbing materials, for instance timber purlins. In such cases the timber should be covered with a strip of asphalt felt or similar material.
  • Minimum roof pitch of No-Con-Drop is 10°.
  • Through flow of air is imperative i.e. See that the interior of the building or the space under the roof is well ventilated, in order to insure that the absorbed moisture will in due course evaporate from the fibre fabric coating.
  • Lower sheet tails and the topsheet at endlaps should be painted with a transparent impregnating liquid or alkyd lacquer.
  • Foam fillers should not be used on the application of No-Con-Drop sheets.
  • Care should be taken to avoid damage to the coating during installation. Storage of the material outdoors should be avoided. However, if this is unavoidable, the material should be satisfactorily covered and should be stored in a manner that will ensure good air circulation, in order to avoid accumulation of moisture.
  • DO NOT walk on the fibre before installation !

Installation

At installation be careful not to damage the fibre when Ira nsporting the sheets over purlins. It is natural that the porous surface of the fibre can be easily soiled. Use therefore clean working gloves when handling the sheets.

Classifications

Both topcoating and the fibre fabric have class I fire-resistant surface as per BS 476 Part 7. The fibre fabric is frost resistant and resistant to mould growth.

Repair of top coating and fibre fabric

Any darmage to the coating during handing should be repaired. Major damage on the fibre fabric can be remedied by bonding a new fibre fabric to the underside. A water resistant adhesive can be used.

For re-laminating, Cladco can supply small quantities of fibre fabric.

Technical service and information

Property Testing Method Unit Value
Composition PE/Synthetic Rubber
Treatment Selfadhesive
Speical characteristics Water absorption
Weight EN 29073-1 h/m ±10%
Thickness EN ISO 9073-2 mm <1
Water absorption 0° 1000*1
Water absorption DIN 53923 g/100cm³ 45° 800*1
Water absorption 90° 600*1
Flammability EN 13501-1 A2-s1,do*1
Strength at break MD ISO 9073-3:1989 N/5mm 144.7
  CD N/5mm 108.9
Elongation at break MD ISO 9073-3:1989 % 53.5
  CD % 83
Peel Adhesion MD N/25mm min 10*1
Adhesion after ageing MD N/25mm improved
Sound absorption EN ISO 354 Hz 125Hz 0.02
500Hz 0.04
1000Hz 0.04
2000Hz 0.12
4000Hz 0.42
Rainfall noise sound in sulation  ISO 140-18 dB 71*2
69*1
2
Thermal conductivity(λ) DIN 52612 W/mK 0.038
Bacteria resistance DIN EN 14119 Index 0-No visible growth under the microscope-50x
Colour Grey Marble